Details
Instructions | |||||||||
1. Single Cell Over Charge Protection Voltage | 3.9V±50mV(Release voltage:3.8V±50mV) | ||||||||
2.Battery Pack Over Charge Protection Voltage | Full charge early alarm:88.0±0.5V,slow alarm(di di di...);Protection:91V±0.5V,Fast alarm then cut off automatically | ||||||||
3.Battery Pack Over Charge Release Voltage | 89.5V±0.5V | ||||||||
4.Single Cell Over Discharge Protection Voltage | 2.10V±50mV(Release voltage:2.3V±50mV) | ||||||||
5.Battery Pack Over Discharge Protection Voltage | Low power early alarm:70.5±0.5V,slow alarm;Low voltage early alarm:57V±0.5V,fast alarm and protection cut off, alarm is just for your information and you can detach alarm if you don't want the sound | ||||||||
6.Battery Pack Over Charge/Discharge Protection Release Condition | Charge battery pack to recover from over discharge:Minimum 62.5±0.5V,Over discharge(low voltage cut-off),Too high current, Short circuit protection can be recovered by charge. | ||||||||
7.Maximal Continuous Discharging Current | 150A-200A | ||||||||
8.Maximal Pulse Discharging Current | 300A | ||||||||
9.Maximal Charging Current | 150A compatible with electric regenerative braking | ||||||||
10.Battery Pack Over Discharge Current Protection Detection Current | 625A±25A | ||||||||
11.Battery Pack Over Charge Protection Detection Maximal Delay Time | 3sec | ||||||||
12.Battery Pack Over Discharge Protection Detection Maximal Delay Time | 1.0sec | ||||||||
13.Battery Pack Over Discharge Current Protection Detection Maximal Delay Time | 50milliseconds | ||||||||
14.Balancing System Working Static State Consume Current | 3.6mA(The voltage of each cells is 3.2V above.) | ||||||||
15.Balancing System Working Static State Consume Current | 1500uA(The voltage of each cells is 2.0V below.) | ||||||||
16.Impedance | 0.5mΩ(The voltage of each cells is 2.5V above.) | ||||||||
17.Dimensions | 1xBalance module(L)238X(W)80X(H)48mm,1xMajor control module(L)238X(W)86X(H)85mm | ||||||||
18.Weight | Balance module:660g;Major control module:1200g | ||||||||
19.Apply to | 24 LiFePO4 Cells in Series 20-200AH | ||||||||
20.Feature | Advanced capacitor balancing technique which provides more efficient cells balance function. It balances cells by transfering energy from higher cell to lower cell(Efficient to 60Ah-200Ah battery pack). Save energy and reduce heat emission in balance process. | ||||||||
21.Installation method | Double Faced Adhesive Tape or screw | ||||||||
22.The voltage of each cells equalization precision | ±5mV---±35mV(The coherence of each cells capacity between±3%0,0.2C discharge testing method) | ||||||||
23.The maximal temperature ascent of balancing system module | Less than25℃ | ||||||||
24.Working temperature range | —20℃-----+65℃ |